- Tridonic
- Prodotti
- Drivers LED
- Filtro
- Generazione 4
- companionSUITE
- Outdoor dimmerabile compatto
- Outdoor dimmerabile lineare IP67/IP66
- Outdoor Fixed-Output lineare IP67
- Industry dimmerabile lineare
- Industry Fixed-Output lineare
- Dimmerabile lineare SELV
- Dimmerabile lineare non-SELV
- Fixed-Output lineare SELV
- Fixed-Output lineare non-SELV
- Dimmerabile compatto
- Serie premium
- LC 10 W 150–400 mA bDW SC PRE2
- LC 17 W 250–700 mA bDW SC PRE2
- LC 25 W 350–1050 mA bDW SC PRE2
- LC 45 W 500–1400 mA bDW SC PRE2
- LCA 10 W 150–400 mA one4all C PRE
- LCA 17 W 250–700 mA one4all C PRE
- LCA 25 W 350–1050 mA one4all C PRE
- LCA 45 W 500–1400 mA one4all C PRE
- LCA 60 W 900–1750 mA one4all C PRE
- LCA 100 W 1100–2100 mA one4all C PRE
- LCA 10 W 150–400 mA one4all SC PRE
- LCA 17 W 250–700 mA one4all SC PRE
- LCA 25 W 350–1050 mA one4all SC PRE
- LCA 45 W 500–1400 mA one4all SC PRE
- LCA 10 W 150–400 mA one4all SR PRE
- LCA 17 W 250–700 mA one4all SR PRE
- LCA 25 W 350–1050 mA one4all SR PRE
- LCA 45 W 500–1400 mA one4all SR PRE
- LCA 60 W 900–1750 mA one4all SR PRE
- LCA 100 W 1100–2100 mA one4all SR PRE
- LCA 38 W 350–1050 mA 2xCH C PRE
- LCA 38 W 350–1050 mA 2xCH SR PRE
- Serie excite
- Serie advanced
- Serie essence
- Tunable White
- Serie premium
- Fixed-Output compatto
- Dimmerabile in-track
- Fixed-Output in-track
- DC-String
- Drivers LED a tensione costante
- Tensione universale (UNV)
- Matter components
- Accessori
- Moduli LED
- Tunable White
- Illuminazione di emergenza
- Comando della luce e connessione
- Drivers LED
- Applicazioni
- Illuminazione connessa in rete
- Progetti
- Servizi
- Dati tecnici
- Contatti
- Home
- Prodotti
- ►
- Drivers LED
- ►
- Dimmerabile compatto
- ►
- Serie premium
- ►
- LCA 25 W 350–1050 mA one4all SR PRE
Driver LCA 25W 350–1050mA one4all SR PRE
Serie premium
Descrizione del prodotto
- NUOVO: lumDATA (DALI-2 parti 251, 252 e 253)
- Driver LED autonomo a corrente costante, due canali a dimming separato, con pressacavi
- Dimmerabile con DALI / DALI-2
- Dimming 1 ... 100 % (in tutto il range di modalità)
- Corrente d'uscita programmabile da 350 a 1.050 mA con programmer ready2mains, I-SELECT 2 Plugs oppure DALI
- Potenza d'uscita max. 25 W
- Efficienza fino al 90 %
- Potenza impegnata in stand-by < 0,15 W
- Durata vita nominale di max. 100.000 h
- 5 anni di garanzia (condizioni su www.tridonic.com)
Caratteristiche armatura
- Copertura: policarbonato, bianco
- Tipo di protezione IP20
- Pressacavi con possibilità di cablaggio passante
Interfacce
- one4all (DALI-2 DT 6, DSI, switchDIM, corridorFUNCTION)
- ready2mains (configurazione e dimming via rete)
- Morsetti: 0° / 45° a innesto (entrata/uscita)
Funzioni
- Corrente d'uscita regolabile a passi di 1 mA (DALI, ready2mains, I-SELECT 2)
- Corrispondente alle parti DALI-2: 251 (dati apparecchi), 252 (report energia)e 253 (diagnosi & manutenzione)
- Funzione Constant Light Output (CLO)
- Fading power-up in AC
- Confiurazione via ready2mains
- Spegnimento del driver con fade2zero
- Il monitor di servizio registra eventi determinati
- Funzioni protettive (sovratemperatura, cortocircuito, sovraccarico, funzionamento a vuoto, tensione d'ingresso consentita, aumento ridotto di corrente d'impulso)
- Idoneo per unità illuminazione d'emergenza conf. EN 50172
- Per conduttori di sezione fino a 2,5 mm²
Vantaggi
- Finestra operativa studiata per la massima compatibilità
- Grande risparmio energetico grazie all'elevata efficienza e al poco consumo in stand-by
- Configurazione flessibile via DALI, ready2mains e I-SELECT 2
- Montaggio senza ausilio di attrezzi
Applicazioni tipiche
- Per downlights, faretti e applicazioni decorative
Dati ordine | ||||
---|---|---|---|---|
Tipo | Numero articolo | Confezione, cartone | Confezione, paletta | Peso unitario |
LCA 25W 350-1050mA one4all SR PRE | 28000671 | 10 pezzo/pezzi | 400 pezzo/pezzi | 0,207 kg |
- Apparecchi di illuminazione:
-
-
-
- Marchi di approvazione:
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Dati tecnici | |
---|---|
Tensione di alimentazione nominale | 220 – 240 V |
Gamma di tensione in AC | 198 – 264 V |
Gamma di tensione DC | 176 – 280 V |
Frequenza di rete | 0 / 50 / 60 Hz |
Protezione contro la sovratensione | 320 V AC, 48 h |
Corrente tipica (a 230 V, 50 Hz, pieno carico) (1) (2) | 95,8 – 128,4 mA |
Corrente tipica (220 V, 0 Hz, pieno carico, livello dimming 15 %) (2) | 94,1 – 129,5 mA |
Corrente derivata (a 230 V, 50 Hz, pieno carico) (1) (2) | < 150 µA |
Massima potenza assorbita | 29,9 W |
Efficienza tipica (a 230 V, 50 Hz, pieno carico) (2) | 90 % |
λ (a 230 V, 50 Hz, pieno carico) | 0,96 |
Tipica potenza assorbita in stand-by (3) | < 0,15 W |
Corrente d'ingresso tipica a vuoto | 28,5 mA |
Tipica potenza assorbita a vuoto | 0,58 W |
Corrente d'accensione (picco / durata) | 25 A / 141 µs |
THD (a 230 V, 50 Hz, pieno carico) (1) | < 7 % |
Tempo di accensione (a 230 V, 50 Hz, pieno carico) (1) | < 0,6 s |
Tempo di accensione (modalità DC) | < 0,33 s |
Tempo di commutazione (modalità AC/DC) (4) | < 0,33 s |
Tempo di spegnimento (a 230 V, 50 Hz, pieno carico) | < 20 ms |
Tolleranza di corrente d'uscita (1) (5) | ± 3 % |
Picco massimo di corrente d'uscita (non ricorrente) | ≤ corrente d'uscita + 40 % |
Corrente d'uscita LF onde residue (< 120 Hz) | ± 2,5 % |
Uscita P_ST_LM (a pieno carico) | ≤ 1 |
Uscita SVM (a pieno carico) | ≤ 0,4 |
Max. tensione d'uscita (U-OUT) | 60 V |
Gamma di regolazione | 1 – 100 % |
Resistenza a picchi di tensione (fra L - N) | 1 kV |
Resistenza a picchi di tensione (fra L/N - PE) | 2 kV |
Tensione d'impulso sul lato d'uscita (contro PE) | < 0,5 kV |
Tipo di protezione | IP20 |
Durata di vita | fino a 100.000 h |
Garanzia | 5 Anno/i |
Dimensioni L x l x H | 200 x 70 x 31 mm |
- (1) Valido ad un livello di dimmerazione del 100 %.
- (2) In funzione della corrente d'uscita impostata.
- (3) In funzione del passaggio di dati DALI sull'interfaccia.
- (4) Vale per il cambio immediato del tipo di alimentazione, altrimenti vale il tempo d'innesco.
- (5) La corrente d'uscita è il valore medio.
Dati tecnici specifici | |||||||||
---|---|---|---|---|---|---|---|---|---|
Tipo | Corrente d'uscita (1) (2) | Min. tensione d'uscita | Max. tensione d'uscita | Potenza d'uscita max. | Potenza impegnata tipica (a 230 V, 50 Hz, pieno carico) | Corrente assorbita tipica (a 230 V, 50 Hz, pieno carico) | Max. temperatura del tc point | Temperatura ambiente ta | Valore resistenza I-SELECT 2 (3) |
LCA 25W 350-1050mA one4all SR PRE | 350 mA | 20 V | 50 V | 17,5 W | 21,0 W | 96 mA | 80 °C | -25 ... +60 °C | – |
LCA 25W 350-1050mA one4all SR PRE | 400 mA | 20 V | 50 V | 20,0 W | 23,7 W | 108 mA | 80 °C | -25 ... +60 °C | 12,50 kΩ |
LCA 25W 350-1050mA one4all SR PRE | 450 mA | 20 V | 50 V | 22,5 W | 26,3 W | 119 mA | 75 °C | -25 ... +55 °C | 11,11 kΩ |
LCA 25W 350-1050mA one4all SR PRE | 500 mA | 20 V | 50 V | 25,0 W | 29,0 W | 130 mA | 75 °C | -25 ... +55 °C | 10,00 kΩ |
LCA 25W 350-1050mA one4all SR PRE | 550 mA | 20 V | 46 V | 25,0 W | 29,0 W | 130 mA | 75 °C | -25 ... +55 °C | 9,09 kΩ |
LCA 25W 350-1050mA one4all SR PRE | 600 mA | 20 V | 42 V | 25,0 W | 28,8 W | 130 mA | 75 °C | -25 ... +55 °C | 8,33 kΩ |
LCA 25W 350-1050mA one4all SR PRE | 650 mA | 20 V | 39 V | 25,0 W | 29,0 W | 130 mA | 75 °C | -25 ... +60 °C | 7,69 kΩ |
LCA 25W 350-1050mA one4all SR PRE | 700 mA | 20 V | 36 V | 25,0 W | 29,1 W | 131 mA | 75 °C | -25 ... +60 °C | 7,14 kΩ |
LCA 25W 350-1050mA one4all SR PRE | 750 mA | 20 V | 33 V | 25,0 W | 29,1 W | 131 mA | 75 °C | -25 ... +60 °C | 6,67 kΩ |
LCA 25W 350-1050mA one4all SR PRE | 800 mA | 20 V | 31 V | 25,0 W | 29,3 W | 131 mA | 75 °C | -25 ... +60 °C | 6,25 kΩ |
LCA 25W 350-1050mA one4all SR PRE | 850 mA | 20 V | 29 V | 25,0 W | 29,4 W | 132 mA | 75 °C | -25 ... +60 °C | 5,88 kΩ |
LCA 25W 350-1050mA one4all SR PRE | 900 mA | 20 V | 28 V | 25,0 W | 29,5 W | 132 mA | 75 °C | -25 ... +60 °C | 5,56 kΩ |
LCA 25W 350-1050mA one4all SR PRE | 950 mA | 20 V | 26 V | 25,0 W | 29,6 W | 133 mA | 75 °C | -25 ... +60 °C | 5,26 kΩ |
LCA 25W 350-1050mA one4all SR PRE | 1.000 mA | 20 V | 25 V | 25,0 W | 29,8 W | 134 mA | 75 °C | -25 ... +60 °C | 5,00 kΩ |
LCA 25W 350-1050mA one4all SR PRE | 1.050 mA | 20 V | 24 V | 25,0 W | 29,9 W | 134 mA | 75 °C | -25 ... +60 °C | 0,00 kΩ |
Ulteriori informazioni
- ready2mains™ (http://www.tridonic.it/it/products/luxcontrol-ready2mains.asp)
- FAQ – Sistemi LED (http://www.tridonic.it/it/faq-led.asp)
- Progetti di riferimento (http://www.tridonic.it/it/progetti-di-riferimento.asp)
- Dichiarazioni ambientali (http://www.tridonic.it/it/dichiarazioni-ambientali.asp)
- Capitolato (http://www.tridonic.it/it/capitolato.asp)
Certificati / Dichiarazioni di conformità | ||
Tipo | Numero articolo | Certificati |
---|---|---|
Certificati () |
I-SELECT 2 PLUG PRE / EXC Accessori
Descrizione del prodotto
- Resistenza preconfezionata per impostazione corrente
- Compatibile con LED driver provvisti di interfaccia I-select 2; non compatibile con I-SELECT (generazione 1)
- Resistenza con isolamento base
- Potenza resistenza 0,25 W
- Tolleranza di ± 2 % in aggiunta alla tolleranza della corrente d'uscita
- Compatibile con LED driver delle serie PRE e EXC
Esempio di calcolo
- R [kΩ] = 5 V / I_out [mA] x 1000
- Utilizzo di resistenze E96
- Tolleranza resistenza 1 %; potenza 0.1 W; necessario isolamento base
- Nel caso il valore di resistenza sia fuori da quelli specificati, si regola automaticamente la corrente minima (se la resistenza è troppo alta) o quella massima (se è troppo bassa)
Dati ordine | |||||||
---|---|---|---|---|---|---|---|
Tipo | Numero articolo | Colore | Sigla | Corrente | Valore resistenza | Involucro imballaggio | Peso unitario |
I-SELECT 2 PLUG 350MA BL | 28001110 | Azzurro | 0350 mA | 350 mA | 14,30 kΩ | 10 pezzo/pezzi | 0,001 kg |
I-SELECT 2 PLUG 375MA BL | 28001111 | Azzurro | 0375 mA | 375 mA | 13,30 kΩ | 10 pezzo/pezzi | 0,001 kg |
I-SELECT 2 PLUG 400MA BL | 28001112 | Azzurro | 0400 mA | 400 mA | 12,40 kΩ | 10 pezzo/pezzi | 0,001 kg |
I-SELECT 2 PLUG 425MA BL | 28001251 | Azzurro | 0425 mA | 425 mA | 11,80 kΩ | 10 pezzo/pezzi | 0,001 kg |
I-SELECT 2 PLUG 450MA BL | 28001113 | Azzurro | 0450 mA | 450 mA | 11,00 kΩ | 10 pezzo/pezzi | 0,001 kg |
I-SELECT 2 PLUG 475MA BL | 28001252 | Azzurro | 0475 mA | 475 mA | 10,50 kΩ | 10 pezzo/pezzi | 0,001 kg |
I-SELECT 2 PLUG 500MA BL | 28001114 | Azzurro | 0500 mA | 500 mA | 10,00 kΩ | 10 pezzo/pezzi | 0,001 kg |
I-SELECT 2 PLUG 525MA BL | 28001960 | Azzurro | 0525 mA | 525 mA | 9,53 kΩ | 10 pezzo/pezzi | 0,001 kg |
I-SELECT 2 PLUG 550MA BL | 28001115 | Azzurro | 0550 mA | 550 mA | 9,09 kΩ | 10 pezzo/pezzi | 0,001 kg |
I-SELECT 2 PLUG 600MA BL | 28001116 | Azzurro | 0600 mA | 600 mA | 8,25 kΩ | 10 pezzo/pezzi | 0,001 kg |
I-SELECT 2 PLUG 650MA BL | 28001117 | Azzurro | 0650 mA | 650 mA | 7,68 kΩ | 10 pezzo/pezzi | 0,001 kg |
I-SELECT 2 PLUG 700MA BL | 28001118 | Azzurro | 0700 mA | 700 mA | 7,15 kΩ | 10 pezzo/pezzi | 0,001 kg |
I-SELECT 2 PLUG 750MA BL | 28001119 | Azzurro | 0750 mA | 750 mA | 6,65 kΩ | 10 pezzo/pezzi | 0,001 kg |
I-SELECT 2 PLUG 800MA BL | 28001120 | Azzurro | 0800 mA | 800 mA | 6,19 kΩ | 10 pezzo/pezzi | 0,001 kg |
I-SELECT 2 PLUG 850MA BL | 28001121 | Azzurro | 0850 mA | 850 mA | 5,90 kΩ | 10 pezzo/pezzi | 0,001 kg |
I-SELECT 2 PLUG 900MA BL | 28001122 | Azzurro | 0900 mA | 900 mA | 5,62 kΩ | 10 pezzo/pezzi | 0,001 kg |
I-SELECT 2 PLUG 950MA BL | 28001123 | Azzurro | 0950 mA | 950 mA | 5,23 kΩ | 10 pezzo/pezzi | 0,001 kg |
I-SELECT 2 PLUG 1000MA BL | 28001124 | Azzurro | 1000 mA | 1.000 mA | 4,99 kΩ | 10 pezzo/pezzi | 0,001 kg |
I-SELECT 2 PLUG 1050MA BL | 28001125 | Azzurro | 1050 mA | 1.050 mA | 4,75 kΩ | 10 pezzo/pezzi | 0,001 kg |
I-SELECT 2 PLUG MAX BL | 28001099 | Azzurro | MAX | MAX | 0,00 kΩ | 10 pezzo/pezzi | 0,001 kg |
CAD / RAY | ||
---|---|---|
Tipo | Numero articolo | Files CAD |
I-SELECT 2 PLUG 350MA BL | 28001110 | CAD (712,6 KB) |
I-SELECT 2 PLUG 375MA BL | 28001111 | CAD (712,6 KB) |
I-SELECT 2 PLUG 400MA BL | 28001112 | CAD (712,6 KB) |
I-SELECT 2 PLUG 425MA BL | 28001251 | CAD (712,6 KB) |
I-SELECT 2 PLUG 450MA BL | 28001113 | CAD (712,6 KB) |
I-SELECT 2 PLUG 475MA BL | 28001252 | CAD (712,6 KB) |
I-SELECT 2 PLUG 500MA BL | 28001114 | CAD (712,6 KB) |
I-SELECT 2 PLUG 525MA BL | 28001960 | CAD (712,6 KB) |
I-SELECT 2 PLUG 550MA BL | 28001115 | CAD (712,6 KB) |
I-SELECT 2 PLUG 600MA BL | 28001116 | CAD (712,6 KB) |
I-SELECT 2 PLUG 650MA BL | 28001117 | CAD (712,6 KB) |
I-SELECT 2 PLUG 700MA BL | 28001118 | CAD (712,6 KB) |
I-SELECT 2 PLUG 750MA BL | 28001119 | CAD (712,6 KB) |
I-SELECT 2 PLUG 800MA BL | 28001120 | CAD (712,6 KB) |
I-SELECT 2 PLUG 850MA BL | 28001121 | CAD (712,6 KB) |
I-SELECT 2 PLUG 900MA BL | 28001122 | CAD (712,6 KB) |
I-SELECT 2 PLUG 950MA BL | 28001123 | CAD (712,6 KB) |
I-SELECT 2 PLUG 1000MA BL | 28001124 | CAD (712,6 KB) |
I-SELECT 2 PLUG 1050MA BL | 28001125 | CAD (712,6 KB) |
I-SELECT 2 PLUG MAX BL | 28001099 | CAD (712,6 KB) |
CAD / RAY | ||
---|---|---|
Tipo | Numero articolo | Files CAD |
LCA 25W 350-1050mA one4all SR PRE | 28000671 | CAD (710,6 KB) |
EPD | ||
---|---|---|
Tipo | Numero articolo | Dichiarazione ambientale del prodotto (EPD) |
LCA 25W 350-1050mA one4all SR PRE | 28000671 | EPD |